BURNERS
Duct Burner
-
✔︎ Duct cross sections: 3 to 50 feet (0.91 to 15.25 meter)
✔︎ Heat inputs: 10 to 1100 MMBtu/hr (2.93 to 322 MW)
✔︎ Inlet oxygen levels: ≥ 10.5% wet without augmenting air
✔︎ Inlet H2O: ≤ 20% without augmenting air
✔︎ TEG distribution to the burner: ± 20% of the average velocity over 90% of the cross section
-
✔︎ Low CO and VOC Emissions
Up to 80% lower than recirculation type burners – including over turndown.✔︎ Low Pressure Drop
Maintained through our patented design with mixing vortices.✔︎ Reliable Light-off
High Energy Spark Ignition (HESI) for consistent performance in low oxygen and high water vapor environments.✔︎ No augmenting air required
With TEG oxygen greater than 10.5% and water vapor as high as 20%.✔︎ Investment Cast stabilizers
Stainless steel stabilizers allow for long life and consistent performance.✔︎ Vortex shedding analysis
Performed on each burner to ensure long life and trouble free operation.✔︎ Patented design
Provides increased mixing that optimizes the existing oxygen in the turbine exhaust.✔︎ Short Flame Lengths
Reduced downstream duct distance and improved temperature distribution from the burner.